Datasheet
|
15KTL3-XL
|
20KTL3-XL
|
25KTL3-XL
|
30KTL3-XL
|
|
Input Data (DC)
|
|||||
Max. recommended PV power
(for module STC) |
19500W
|
26000W
|
325000W
|
39500W
|
|
Max. DC voltage
|
1100V
|
||||
Start voltage
|
250V
|
||||
Nominal voltage
|
360V
|
||||
MPPT voltage range
|
200V-1000V
|
||||
No. of MPP trackers
|
3
|
||||
No. of PV strings per MPP tracker
|
4/4/4
|
||||
Max. input current per MPP tracker
|
46A/46A/46A
|
||||
Max. short-circuit current
per MPP tracker |
50A/50A/50A
|
||||
Output data(AC)
|
|||||
AC nominal power
|
15000W
|
20000W
|
25000W
|
30000W
|
|
Max. AC apparent power
|
16600VA
|
22200VA
|
27800VA
|
33300VA
|
|
Nominal AC voltage(range*)
|
127V/220V(101.6-139.7V)
|
||||
AC grid frequency(range*)
|
50/60 Hz(46~54/56~64Hz)
|
||||
Nominal AC output current
|
39.4A
|
52.5A
|
65.6A
|
78.8A
|
|
Max. output current
|
43.6A
|
58.3A
|
73.0A
|
87.4A
|
|
Power factor(@nominal power)
|
>0.99
|
||||
Adjustable power factor
|
0.8leading…0.8lagging
|
||||
THDi
|
<3%
|
||||
AC grid connection type
|
3W+N+PE
|
||||
Efficiency
|
|||||
Max.efficiency
|
98.8%
|
||||
European efficiency
|
98.2%
|
||||
Protection Devices
|
|||||
DC reverse polarity protection
|
Yes
|
||||
DC switch
|
Yes
|
||||
AC/DC surge protection
|
Type II
|
||||
Insulation resistance monitoring
|
Yes
|
||||
AC surge protection
|
Type II
|
||||
AC short-circuit protection
|
Yes
|
||||
Grid monitoring
|
Yes
|
||||
Anti-islanding protection
|
Yes
|
||||
Residual-current monitoring unit
|
Yes
|
||||
String fuse protection
|
No
|
||||
String monitoring
|
No
|
||||
Anti-PID function
|
No
|
||||
AFCI protection
|
No
|
||||
General Data
|
|||||
Dimensions (W / H / D)
|
680/508/281mm
|
||||
Weight
|
≤52kg
|
||||
Operating temperature range
|
-25°C ... +60°C
(>45°C Derating)
|
||||
Noise emission (typical)
|
≤60dB(A)
|
||||
Nighttime power consumption
|
1W
|
||||
Topology
|
Transformerless
|
||||
Cooling
|
Smart air cooling
|
||||
Protection degree
|
IP65
|
||||
Relative humidity
|
0-100%
|
||||
Altitude
|
4000m
|
||||
DC connection
|
H4(OPT)
|
||||
AC connection
|
OT Terminal
|
||||
Display
|
OLED+LED/WIFI+APP
|
||||
Interfaces:RS485/USB
/WiFi/GPRS |
Yes/Yes /Optional/Optional/Optional
|
Payment Terms | T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. |
FOB | |||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | ||
CIF | |||
L/C | Optional for the amount of above 50,000 usd, L/C at sight is acceptable. | ||
West Union | Optional for amount of order less than 5000 usd | ||
Paypal | |||
Delivery Time | 7-25 days after receiving the payment or the deposit payment |