Loctite 510 Anaerobic Flange Sealant Adhesive Replacement

Model NO.
510
Material
Acrylic
Classification
Room Curing
Main Agent Composition
Acrylic
Characteristic
Waterproof
Promoter Composition
Curing Agent
Composition
Organic Material
Color
Purple
Free Sample
Yes
Customized Package
Yes
Private Label Service
Yes
Shelf Life
3 Years
Transport Package
60PCS/Carton
Specification
50ml/tube, 310ml/carteidge
Trademark
Customized
Origin
China
HS Code
3506100010
Production Capacity
500000PCS/Month
Reference Price
$ 1.80 - 16.20

Product Description

Red Anaerobic Flange Sealant 1510 310ml/tube, Equal to Loctite 510. 

High temperature resistance. Rigid adhesive layer will be formed after cured. For sealing rigid flanges, end caps or used as gasket coating.
 

Loctite 510 Anaerobic Flange Sealant Adhesive Replacement

Application

 

(1) Fill the gap of 0.2mm, it seals colse fitting joints between rigid metal surfaces and flanges and will flex with minor flange movements.

 

(2) used as a form-in-place gasket for pumps, thermostats, compressors, transmission housings and axle covers. especially sealing of the rigid-structured flange in gear boxes, engine crankcases, and flange plates, etc.


 

Characteristics

One-part, general purpose, high intensity anaerobic flange sealant, can replace any gasket instantly, good medium resistance, can form a soft layer after cured.

It cured when confined in the absence of air between close fitting metal surfaces.


 
Physical Properties
 

Color:

Pink                 

Specific gravity:

1.10g/cm³

Viscosity(GB/T2794):

5.0x10 5 mPa•s

Max sealing clearance:                                  

0.25mm

Max sealing pressure(JB/T7311):

36.5MPa

Fixture time:

2~3h

Fully cured time: 24h

Temperature range:

-60~204ºC




Package Available

50ml/tube, 60pcs/carton
310ml/cartridge, 30pcs/carton
 

User's Guide

 

1. For best performance bond surfaces should be clean and free from grease.

2. The product is designed for close fitting flanged parts with gaps up to 0.25mm.

3. Apply manually as a continuous bead or by screen printing to one surface of the flanges.

4. Low pressures (<0.2mm) may be used when testing to confirm a complete seal immediately after assembly and before curing.

5. Flanges should be tightened as soon as possible after assembly to avoid shimming.