Type designation
|
SG33CX
|
SG40CX
|
SG50CX
|
SG110CX
|
Max. PV input voltage
|
1100 V
|
|||
Min. PV input voltage / Start-up input voltage
|
200 V / 250 V
|
|||
Nominal PV input voltage
|
585 V
|
|||
MPP voltage range
|
200 - 1000 V
|
|||
MPP voltage range for nominal power
|
550 - 850V
|
|||
No. of independent MPP inputs
|
3
|
4
|
5
|
9
|
Max. number of PV strings per MPPT
|
2
|
2
|
2
|
2
|
Max. PV input current
|
78 A
|
104 A
|
130 A
|
26 A * 9
|
Max. DC short-circuit current
|
120 A
|
160 A
|
200 A
|
40 A * 9
|
Type designation
|
SG33CX
|
SG40CX
|
SG50CX
|
SG110CX
|
AC output power
|
33 kVA @45 ºC, 400Vac / 36.3 kVA @ 40 ºC,400Vac 33 KVA@50 ºC, 415Vac / 36.3 KVA@45 ºC, 415Vac
|
40 kVA @45 ºC, 400Vac / 44 kVA @ 40 ºC,400Vac 40 KVA@50 ºC, 415Vac / 44 KVA@45 ºC, 415Vac
|
50 kVA @45 ºC, 400Vac / 55kVA @ 40 ºC,400Vac 50KVA@50 ºC, 415Vac / 55kVA @ 45 ºC,415Vac (Australia: max. 50 kVA)
|
110 kVA @ 45 ºC / 100 kVA @ 50 ºC
|
Max. AC output current
|
55.2 A
|
66.9 A
|
83.6 A
|
158.8 A
|
Nominal AC voltage
|
3 / N / PE, 230 / 400 V
|
|||
AC voltage range
|
312 - 528 V
|
320 - 460 V
|
||
Nominal grid frequency / Grid frequency range
|
50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
|
|||
THD
|
< 3 % (at nominal power)
|
|||
DC current injection
|
< 0.5 % In
|
|||
Power factor at nominal power / Adjustable power factor
|
> 0.99 / 0.8 leading - 0.8 lagging
|
|||
Feed-in phases / connection phases
|
3 / 3
|
|||
Max. efficiency / European efficiency
|
98.6 % / 98.3 %
|
98.6% / 98.3%
|
98.7% / 98.4%
|
98.7 % / 98.5%
|
Type designation
|
SG33CX
|
SG40CX
|
SG50CX
|
SG110CX
|
Dimensions (W*H*D)
|
702*595*310mm
|
782*645*310mm
|
782*645*310mm
|
1051*660*362.5 mm
|
Weight
|
50 kg
|
58 kg
|
62 kg
|
89 kg
|
Isolation method
|
Transformerless
|
|||
Degree of protection
|
IP66
|
|||
Night power consumption
|
≤2 W
|
|||
Operating ambient temperature range
|
-30 to 60 ºC
|
|||
Allowable relative humidity range (non-condensing)
|
0 - 100 %
|
|||
Cooling method
|
Smart forced air cooling
|
|||
Max. operating altitude
|
4000 m (> 3000 m derating)
|
|||
Display
|
LED, Bluetooth+APP
|
|||
Communication
|
RS485 / Optional: Wi-Fi, Ethernet
|
|||
DC connection type
|
MC4 (Max. 6 mm²)
|
|||
AC connection type
|
OT or DT terminal (Max.70 mm²)
|
OT / DT terminal (Max. 240 mm²)
|
||
Compliance
|
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4105:2023, VDE-AR-N 4110:2023, IEC 61000-6-3, EN 50549, AS/NZS
4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA |
|||
Grid Support
|
Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control
|