Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump

Model NO.
EDJ
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Impeller
Semi-Open
Usage
Pump, Pumps
Other Specs.
Electric Main Pump+Stand by Diesel Pump+Jockey P
Pump Specs.
250gpm,300gpm,350gpm,500gpm,750gpm,1000gpm,1500gpm
Accessories of Diesel Engine
Water Tank,Fuel Tank,Exhaust Muffler,Charger and 2
Electric Motor Specs.
50Hz or 60Hz, 380V,400V,or 415V,440V,6kv,10kv
Coupling
Flexible Coupling
Impeller Material
Cast Iron,Ductile Iron,Stainless Steel,Bronze
Driven
Electric Motor & Diesel Engine
Shaft
2Cr13,45#Steel,Stainless Steel
Pump Material
Cast Iron, Ductile Iron,Stainless Steel
Color
Red
Transport Package
Standard Export Wooden Case
Specification
NFPA20, CE, ISO
Trademark
Pacific Pump
Origin
Shanghai China
HS Code
8413709990
Production Capacity
2000 Set/ Year
Reference Price
$ 900.00 - 9,000.00

Product Description

Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump

EDJ Diesel Electric Fire Pump Jockey Pump with Control Panel Packing

EDJ fire pump : EDJ series is a packaged fire pump set,generally an automatic fire water supply system consists of a main pump (driven by an electrical motor),stand by pump (driven by diesel engine) and a jockey pump.This model comes equipped with a separate controller,or one that is attached to the skid,The package also contains discharge valves,common header,and accessories.

Working principle:generally the pipeline network's pressure is between the low pressure P1 and the high pressure P2.When the above pressure is lower than P1,the pressure maintaining pump will start automatically and not stop until the pressure rises gradually to P2.Due to the pipeline network's leakage,its pressure will drop to P1 gradually,and then the pressure maintaining pump will start automatically again.with such a repeated process,the pipeline network's pressure is maintained between P1 and P2 all the time.when the pipeline network's pressure can't be maintained between P1 and P2 (for instance,when the water consumption increases a lot) and drops to the minimum pressure P3,the electric pump will start automatically and the pressure will rise to Pw and meet the need for fire water supply,if the mains supply is power-off or the electric pump fails,the pressure will continue to drop from P3 to the ultimate pressure P4.then the diesel pump set will start automatically,and the pressure will rise to Pw and meet the need for fire water supply.the electric or diesel pump shall be stopped manually after human judgment (except automatic switching )
Introdution

Fire pump system is made of  Electric Pump  +  Diesel Engine Pump + Jockey Pump+Accessories

Operation: 1 Duty(electric pump ) + 1 stand by(diesel engine ) + 1 Jockey

Capacity: 100GPM, 150GPM, 200GPM, 300GPM, 400GPM, 500GPM, 750GPM, 1000GPM, 1250GPM...GPM with Pressure 4Bar, 5bar, 6Bar, 10Bar, 15Bar... Bar.

Application: Equipment for warehouses, docks, airports, petrochemical, power plants, liquefied gas, textiles, ships, oil tankers and other occasions of a fire service.

Working Conditions : Altitude ≤ 1000m; Ambient temperature: +5 °C ~ +40 °C; Relative humidity: <= 90%.

Features
1)Safe and reliable 
2)Easy installation  3)Easy to operation  4)International standard 
5)Use foreign advanced technology

Performance range

Flow >25GPM ,

Head 20~230m ,

Power >5.5KW,
Pump material:
Diesel and electric fire Pump Material Construction:Pump casing&cover is made of cast iron and impeller is made of bronze,shaft is made of 2Cr13;
Diesel Fire Pump - - Scope of Supply:Pump,diesel engine,auto control panel,flexible coupling,coupling guard,common base plant,packing.
Accessories of diesel engine:Water tank,fuel tank,exhaust muffler,charger and 24v storage battery.

Working condition

1.It can transport clear water or other liquid that the physical and chemical properties are similar to clear water, its solid insoluble things does not exceed 0.1%.

2.Medium temperature: -15 to 120 .

3.The greatest working pressure ,Model XBD pump: ≤ 2.5 Mpa, namely systematic pressure + delivery head ≤ 2.5 Mpa, XBD ( ) type pump. ≤ 2.0 Mpa.

4.The environment temperature is not greater than 40 , the relative humidity is smaller than 95%.


Configuration :

OPTIONS PICTURES FOR REFERENCE ( U CAN CHOOSE THE TYPE U PREFER)
1-EDJ Type (Electric Pump+Diesel Pump+Jokey Pump) Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump
 
2-DJ Type (Diesel Pump+Jokey Pump) Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump
 
3-EJ Type (Electric Pump+Jokey Pump) Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump
 
4-EEJ Type (Electric Pump+Electric Pump+Jokey Pump) Electric Motor Fire Pump +Diesel Engine Fire Pump+Jockey Pump with Accessories, Edj Fire Pump, Split Case Pump, Double Suction Pump