12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter

Model NO.
MY LS-5000W
Application
Home, Industrial, Commercial
Specification
Normal, 565*395*225~585*415*225mm
Output Type
Single
Output Frequency
50/60Hz±1%
Weight
13~27kg
Technology
CPU Control
Protection
Overload,Over Circuit
Output Waveform
Pure Sine Wave
Color
Orange
Type
DC/AC Inverters
Output Current
0~30A
Display
LCD
Overload Capacity
Air Condition, Water Pump and So on
Product Name
1kw 2kw 3kw 4kw 5kw 6kw off Grid Inverter
Output Voltage
110VAC±2% / 220VAC±2%
Transfer Time
4ms
Transport Package
Carton
Trademark
MY SOLAR/OEM/ODM
Origin
China
HS Code
8503009090
Production Capacity
10000PCS/Month
Reference Price
$ 100.80 - 111.60

Product Description

12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter
Parameters

 

Specification
Model LS 10212/24 20232/24/48 30224/48 40224/48 50248 60248
Rated Power 1000W 2000W 3000W 4000W 5000W 6000W
Peak Power(20ms) 3000W 6000W 9000W 12000W 15000W 18000W
Start Motor 1HP 2HP 3HP 3HP 4HP 4HP
Battery Voltage 12/24VDC 12/24/48VDC 24/48VDC 24/48VDC 48VDC
Size(L*W*Hmm) 490*300*130 510*320*140
Packing Size(L*W*Hmm) 565*395*225 585*415*225
N.W.(kg) 11.5 17.5 19.5 21.5 23.5 25.5
G.W.(kg)(Carton Packing) 13 19 21 23 25 27
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 85VAC~138VAC / 170VAC~275VAC 
AC Input Frequency Range 45Hz~65Hz
Max AC charging current 25A/15A 30A/25A/15A 30A/20A 30A/25A 30A 30A
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2%  / 220VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10%  / 220VAC±10% 
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤0.8% rated power
No load loss(AC Mode)  ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Battery Type
(selectable)
LEAD Charge Voltage:14V;Float Voltage:13.8V(12V system; 24V system x2; 48V system x4)
OP-LE Charge Voltage:14.2V; Float Voltage:13.8V(12V system; 24V system x2; 48V system x4)
LITHIUM Charge Voltage: 12.6V(NMC battery 3S)  (12V system; 24V system x2; 48V system x4)
Customize battery Charge and discharge parameters of different types of batteriescan be customized according to user requirements
Protection Battery undervoltage alarm 11V; LITHIUM 9.5V(NMC battery 3S)(12V system; 24V system x2; 48V system x4)
Battery undervoltage protection 10.5V;  LITHIUM 9V(NMC battery 3S)(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarm Lead acid battery: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protection Lead acid battery: 17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltage Lead acid battery: 14.5V(12V system; 24V system x2; 48V system x4)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode MPPT or PWM
Charging current 10A/20A/30A/40A/50A/60A/80A/100A 
PV Input Voltage Range PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system)
Max PV Input Voltage(At 25ºC) PWM: 50V(12V/24 system), 100V(48V system );   MPPT: 150V 
PV Array Maximum Power 12V system: 140W/280W/420W/560W/700W/840W/1120W/1400W;  
24V system: 280W/560W/840W/1120W/1400W/1680W/2240W/2800W;
48V system: 560W/1120W/1680W/2240W/2800W/3360W/4480W/5600W
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication RS232/RS485(Optional)
Environment Operating temperature ≤55dB
Storage temperature -10ºC~40ºC
Noise -15ºC~60ºC
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Warranty 1 year
Note: All specifications are subject to charge without prior notice


12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter

1. Battery number and capacity should be configured according to the rated voltage of the solar power system or invertor;

2. We offer 3 optional working modes (transfer time≤4ms):

01 Grid priority mode:  When the grid and battery are connected to the invertor, grid will supply power to the loads directly after voltage being stabilized and charge batteries via invertor. When the grid is cut off, the battery will automatically continue to supply power via invertor. 
02 Energy saving mode:   If the power of the connected AC loads is lower than 5% of the invertor's rated power, there will be no output from the invertor. Only the chip of invertor is working. The power consumption of the invertor is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the invertor will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode:   When the grid and battery are connected to the invertor, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.


12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter 12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods. 
12V 220V 5000W Hybrid Inverter 1000W 1500W 2000W 3000W 4000W 6000W Inversor Solar 24V 48V 110V 120V Pure Sine Wave Inverter

Q1: Are you a factory?
A: Yes, we are ISO9001:2015 manufacturing with qualifications of TUV, CE, ROHS & CCC. main products including inverter, solar controller and solar energy system solution.

 

Q2: Are you inverter pure sine wave output?
A: Yes, all of our inverter are pure sine wave output.

 

Q3: What kind of output you can do?
A: Normally, we produce inverter with 110v/ 50Hz, 120V/ 60Hz, 220v/ 50Hz, 230v/ 50Hz, 240V/50Hz.
If you have special requirements, pls tell us for engineer consulting.

 

Q4: What appliances your inverters can load?
A4: Our inverter can load household appliances other inductive load such as refrigerator, air condition, water pump, etc.

 

Q5: How long is your factory?
It's over 10 years. at the beginning our factory focused on domestic market.
From 2012, we set up our oversea sales department.

 

Q6: What' s the difference between low frequency and high frequency inverter?

A: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.

 

Q7: What's the difference between pure sine wave inverter and modified sine wave inverter?

A: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution, enviromental-friendly and appliances protected.
Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.

 

Q8: How to solve the technical problem?

A: 24 hours after-service consultancy just for you and to make your problem to solveeasily.

 

Q9: What to do if the product is broken?

A: Usually we do standard exporting package and insurance in case of broken. If any product is faulty, please send us the picture or video, we will study it and supply the spare parts of PCB board free for after sale service.