off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw

Model NO.
SMSH-20KW
Connect
Connection Drawing Provided
Delivery Period
7-15days After Receive Payment
PV Array Combiner
 IP65
Battery Type
Free Maintenance Gel Battery
Solar Power Generator Technology
Ipm or IGBT of Mitsubishi
Solar Cell
Poly Crystalline 156
Battery
12V/200ah X 24PCS
Solar Power Generator Battery
Maintenance-Free Lead-Acid Battery
Special Design
Accept
Controller
 Intelligent Controller
Max. DC Input Power
10kw
PV Mounting Bracket
Flat Ground or Roof, or Pitch Roof
Solar Panel Rack
Optional
Transport Package
Carton or Wood Boxes
Trademark
SUNMASTER
Origin
Zhejiang
HS Code
8502390000
Production Capacity
50, 000 PCS/Year
Reference Price
$ 900.00 - 3,150.00

Product Description


off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Connecting Diagram
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Configuration List

off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Item Certification Description Q'ty Warranty
Solar panel TUV / IEC / EC Mono or Poly 2 pcs 20 years
Inverter CGC / CQC / VDE One (MPPT) tracking/ 50/60Hz; 230Vac 1500W/ SM-SH1500W 1 set 5 years
Distribution box
(Optional)
CE Lighting Protection. Air switch,Fusegar, knifeswitch, 1 set 5 years
Mounting system CE Slant roof bracket/ Cement Ground bracket/ Soil ground bracket 1set 10 years
PV cable TUV/ UL DC port PV1-F 1*4mm² 20m 10 years
AC port YJV-3*6mm² 10m 10 years

off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
 
Solar Panel
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Type MONO POLY
Power class 280W 335W 270W 320W
Open Circuit Voltage (Voc) 43 44 43 43.8
Short Circuit Voltage (Isc) 8.35 9.92 8.23 9.42
Max power Voltage (Vmp) 36 36 36 36.5
Max Power Current (Imp) 7.78 9.3 7.35 8.76
Efficiency ≥17.1% ≥17.2% ≥16.5% ≥16.4%
Dimension (mm) 1650x991x35 1960x991x35 1650x991x35 1960x991x35
Weight (kg) 18±5% 22.5±5% 18±5% 22.5±5%
 
Solar Inverter
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Ambient temperature range -25~+60ºC(>45ºC deloading)
Relative humidity 0~95%
Max operating altitude 4000m (>3000m derating)
Protection degree IP65
Topology Transformerless
Night power consumption (W) <1
Cooiong method Natural convection
Noise emision (dB) <25
Display LCD
Warranty (Year) 5/10/15/20/25 (Optional) Years
 
Solar Controller
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Rated Charge current(A) 40A
Rated DC voltage(V) 24/48 automatic identification
Solar input  Max voltage(V) 42/84
Battery Over charge protective voltage(V) 28.6/57.2
Battery Over charge recover voltage(V) 27.4/54.8
Battery Constant charge voltage(V) 27/54
Battery Over discharge alarm voltage(V) 20/40
Environment Humidity  and temperature 0-90%  No condense,55ºC
Protective Functions Protection against anti-charge at night,battery over charge, over discharge protection,Joint-reversed of solar modules
 
Solar Battery

off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Nominal Voltage 12V
Nominal Capacity 100Ah(10hr,1.80V/cell,25ºC)
Approximate Weight 27.5 kg
Internal Resistance 5.5  mΩ(Lead terminal)
Terminal Lead wire(4.0mm²×1.8m)
Maximum Charge Current 25 A
Ambient Temperature -35~55 ºC
Dimension Length 329mm(±2 mm)
Width 172mm(±2 mm)
Container Height 214mm(±2 mm)
Total Height 236mm(±2 mm)
Case ABS
 
PV Combiner Box
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Components Parameter Function
Circuit breaker (Air switch) 40A When the current of the protected,circuit exceeds the specified value,the circuit breaker will automatically break off to protect the whole circuit.
Fusegear 40A When the current of the protected circuit exceeds the specified value,fusegear will break off automatically
Surge protective device (SPD) UC:420V lmax:20KA
In: 10KAUp≤1.8KV
Photovoltaic lightning protection device
One phase self dual over voltage protection device Working range 220V,50Hz,
over voltage protection
Uvo=270V±5V
Under voltage protection
Uoe= 170±5V
When the circuit voltage is highet or lower, it will shut down automatically.when the voltage reaches standard level, it will recover automatically.
Knife switch / automatic/ by hand

off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw
Conductor Tinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5
Insulation Polyolefin Copolymer electron-beam coss-linked
Sheath Jacket Polyolefin Copolymer electron-beam coss-linked
Nominal Voltage Uo/U=600V/1000VAC, 1000V/1800VDC
Test  Voltage 6500V, 50Hz, 5Min
Temperature Rating -40°C-125°C ,More than 25 Years  (TUV)
Fire Performance IEC 60332-1
Smoke Emission
Low Fire Load DIN 51 900
Certification TUV 2PFG 1169/08 2007 PV1--F
 
Mounging System
off Grid Solar Power System 1 Phase 3 Phase 10kw 20kw

The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters

The whole system has strong safety performance.

Can be customized based on customer's cactual situation

The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground




 

 

Solar Energy System