Product Parameters
Technical Specifications | ||||
MODEL | Grandglow TSC 3000 I | Grandglow TSC 5000 I | Grand glow TSC 8000 I | Grandglow TSC 10000 I |
INPUT | ||||
Minimum input Voltage DC | 48VDC | 48VDC | 96VDC | 96VDC |
OUTPUT | ||||
Rated Power | 3000W | 5000W | 8000W | 10000W |
Output Current | 4.5A*3 | 7.6A,3 | 12A*3 | 15A*3 |
Output Rated VoltageAC | 380VAC±5% | 380VAC15% | 380VAC±5% | 380VAC±5% |
Output Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Size(mm) | 350*600*650 | 350*600*650 | 400*700*740 | 400*700*740 |
Weight(kg) | 73 | 83 | 100 | 125 |
GENERAL DATA | ||||
Output Waveform | Pure sine wave | |||
Conversion Time | 1s | |||
THD | <3% | |||
Noise | <=55dB | |||
Inversion Efficiency | >=85% | |||
Peak Overload Capacity | > 120%, 10s protection 5S protection at 150% | |||
Protective Function | Battery undervoltage protection, mains overvoltage and undervoltage p inverter overload, overvoltage, overtemperature, short circuit, overvoltage and undervoltaqe automatically resume operation after the volt | otection, 3ge is normal | ||
Environment Temperature | -10°C~ 50°C | |||
Environment Humidity | <90%RH,No condensation | |||
Altitude | <2000m | |||
MODEL | Grandglow TSC 3000 I | Grandglow TSC 5000 I | Grand glow TSC 8000 I | Grandglow TSC 10000 I |
INPUT | ||||
Minimum input Voltage DC | 240VDC | 360VDC | 492VDC | 492VDC |
Input State Grid Voltage AC | 380VAC | 380VAC | 380VAC | 380VAC |
OUTPUT | ||||
Rated Power | 30000W | 50000W | 80000W | 100000W |
Output Current | 45A*3 | 75A*3 | 121A*3 | 150A*3 |
Output Rated VoltageAC | 380VAC±5% | 380VAC±5% | 380VAC±5% | 380VAC±5% |
Output Frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Size(mm) | 600*700*1360 | 600*800*1800 | 700*800*1960 | 800*1000*2200 |
Weight(kg) | 298 | 380 | 470 | 576 |
GENERAL DATA | ||||
Output Waveform | Pure sine wave | |||
Conversion Time | Is | |||
THD | <3% | |||
Noise | <55dB | |||
Inversion Efficiency | >85% | |||
Peak Overload Capacity | > 120%, 10s protection 5S protection at 150% | |||
Protective Function | Battery undervoltage protection, mains overvoltage and undervoltage protection, inverter overload, overvoltage, overtemperature, short circuit overvoltage and undervoltage automatically resume operation after the voltage is normal | |||
Environment Temperature | -10°C- 50°C | |||
Environment Humidity | <90%RH,No condensation | |||
Altitude | <2000m | |||
Note: can be customized according to customer requirements |