Plate fiber laser cutting machine
24035
Features
1. Super large format working area, suitable for a variety of cutting scenes
2. Support safety light barrier to ensure production safety
3. 48-grid partition dust dedusting, intelligent control function, and greatly improve the effect
4. The transmission system adopts international famous brands, with stable transmission, fast speed and high positioning accuracy.
5. Add an intelligent monitoring system to track the cutting state in real time and reduce the accident rate.
6. Add obstacle avoidance system and automatic edge patrol system to improve cutting effect and efficiency.
7. Hollow module header, easy and fast disassembly and assembly
Model | 13025 | 13035 | 24035 | 26035 |
Cutting range | 13000*2500mm | 13000*3500mm | 24000*3500mm | 26000*3500mm |
Mechanical positioning accuracy | ±0.05mm/m | |||
Mechanical repeated positioning accuracy | ±0.03mm/m | |||
Maximum acceleration | 0.8G | |||
Maximum positioning speed | 80m /m in | |||
Laser power | 6KW-12KW | |||
Other dimensions can be customized |
HIWIN guide rail YASKAWA motor
Shimpo reducer MAX laser resource (IPG / raycus / JPT options)
The schematic diagram shows the partition dust removal
Fourth generation aviation aluminum high-pressure cast aluminum beam
The whole equipment bed adopts split bed design to improve the overall stiffness, enhance the local stiffness and strengthen the contact stiffness
Maintenance period | Maintenance contents | Maintenance contents |
Every day | 1. Check whether the temperature setting of the chiller is normal (the set temperature is 20 ± 1 ºC ) ; | Ensure that the temperature of the cooling water supplied to the laser is normal |
2. Check whether the water seal, water temperature and water pressure of the chiller meet the requirements; | Ensure the normal operation of the equipment and prevent water leakage | |
3. Ensure that the working environment of the chiller is dry, clean and ventilated; | It is conducive to the good operation of the chiller | |
Monthly | 1. Use neutral detergent or high-quality soap to remove the dirt on the surface of the chiller. Do not use benzene, acid, grinding powder, steel brush, hot water, etc; | Ensure that the surface of the chiller is clean |
2. Check whether the condenser is blocked by dirt. Please remove it with compressed air or brush to ensure that the surface of the chiller is clean; | Ensure the normal operation of the condenser | |
3. Clean the air filter screen:
a. Open the panel of the assembled air filter, pull up the air filter screen of the unit and draw it out; b. The dust on the filter screen can be removed by vacuum cleaner, air spray gun and brush. After cleaning, if the filter screen is wet, shake it to dry and then replace it. c. Cleaning cycle: once every two weeks. If the dirt is serious, please clean it irregularly. |
Prevent poor cooling caused by poor heat dissipation and burning out the water pump and compressor | |
4. Check the water quality of the water tank and follow up; | Good water quality can ensure the normal operation of the laser | |
5. Check whether there is water leakage in the water cooler pipeline ; | Ensure that there is no water leakage in the chiller | |
Quarterly | 1. Check the electrical components (such as switches, terminals, etc.) and wipe them clean with a dry cloth; | Ensure that the surface of the electrical parts of the chiller is clean and prolong the service life |
2. Replace the circulating water (distilled water) and clean the water tank and metal filter screen;
If equipped with ROFIN laser resources, the cooling water can be replaced once every six months after adding an anti-corrosion inhibitor. If equipped with PRC laser resources, the cooling water can be replaced once every six months after adding propylene glycol; |
Ensure that the laser operates normally | |
Attention:
a. Place the chiller and water pipe away from dust. b. Pull the power cord away from the socket and wipe the power cord clean; c. Cleaning the unit body. when cleaning the inside of the unit, do not let water splash on electronic parts; d. Completely drain the water from the laser resource, cutting head and water cooler. |