Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc

Model NO.
HFNC-001
Return and Replacement Product Name
High Flow Nasal Cannula(Hfnc) Oxygen Therapy
Application
Hospital (ICU/Ricu)
Fio2
21%-100%
Accuracy of Fio2
3%
Flow Meter(Lpm)
0.1-1, 1-10, 2-18, 1-15, 6-60, 10-120
Blender Alarm
When Gas Supply Pressure Difference > 0.1 MPa
Blender Alarm Noise
>57 dB(a)
Humidifier Supply
220V/ 110V 50/60Hz
Humidifier Temp
0-75ºC
Transport Package
Carton
Specification
63*62*11.5cm&55.5*38.5*48.5cm
Trademark
UN Medical
Origin
China
HS Code
9019200090
Production Capacity
5000/Year
Reference Price
$ 900.00 - 1,800.00

Product Description

UN-Medical High-flow Heated Respitatory Humidifier HFNC with 6-60lpm 

Model:HFNC-001

Adult / Infant HFNC Machine:
 
· Medical device treatment: In addition to drug treatment, respiratory support treatments relying on medical devices, such as oxygen therapy, invasive mechanical ventilation, extracorporeal membrane oxygenation (ECMO), and circulatory support are of much helpful to those the most serious cases of pneumonia. It also plays an important role in the treatment of critically ill patients. It is time to introduce our high flow oxygen blender for replacement. It is very helpful for the early infection cases and the recovery patients from critical stages.
 
· High Flow Nasal Cannula(HFNC) oxygen therapy is a form of non -invasive respiratory support , which comprises an air oxygen blender , an active humidifier , a single heated circuit and a nasal cannula . It delivers adequately heated and humidified medical gas up to 10-60L/min , and is considered to have a number of physiological effects: reduction of anatomical dead space, PEEP effect, constant fraction of inspired oxygen and good humidification. It is widely used in RICU and ICU .

Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Specification:
 
Adjustment Method of Oxygen Concentration Merchanical
FiO2 21%-100%
Flow 2-18LPM;1-10LPM and 10-120LPM
Pressure of gas source Air/Oxygen @ 0.3-0.4 Mpa
Blender Alarm When gas supply pressure difference > 0.1 Mpa
Blender Alarm Noise >57 dB(A)
Accuracy of FiO2 3%
Humidifier Supply Voltage/Frequency 220V/ 110V 50/60Hz
Humidifier Temperature monitoring 0-75ºC
Humidifier Heater Plate Over-temperature Cut Off 95±5ºC
Heater Wire(Max.) 22V-,2.73A, 60W, 50/60Hz
Humidifier Temperature control settings Heated wire mode(mode indicator lighted)
Temperature grade(with indicator status)  Continuous flow range  Delivered patient temperature
P1 (
· ○○)                                                            5L/min-60L/min            25-29ºC

P2 (
·· ○)                                                            5L/min-60L/min            29-35ºC

P3 (
··· )                                                            5L/min-60L/min            35-39ºC
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details)


Configuration and Package:

Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Multiple Choices:
Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Applications and Custom Choices:

HFNC Machine without Medical Air Compressor(Above)
HFNC Machine with Medical Air Compressor(Below)

Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Company Profile:

We, Wuhan Union Medical Technology CO., Ltd , is a R&D company in patient monitoring solutions, which started in 2009 with leading engineers in China, and established in 2013. Union Medical is committed to the techniques and products of monitoring, diagnosing, supporting and treating the biological information; serving the society; improving human health.

Exhibitions Image 
Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Factory  Image 

Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Un-Medical Adult High Flow Oxygen Therapy Nasal Cannula Hfnc
Shipment and payment 

For the order which less than 20units, more of the customers choose the shipment by Express Courier or by Air Cargo.
Our normal Lead Time is within 5-7working days after payment.


Contact person: Shirley