Medical Air Oxygen Blender Air Oxygen Mixer

Model NO.
UN3000
Application
Hospital (ICU/Ricu)
Number of Output Port
Single or Dual
Flow Meter(Lpm)
0.1-1, 1-10, 2-18, 1-15, 6-60, 7-70, 10-80, 10-120
Fio2 Range
21%-100%
Accuracy
+/-3%
Blender Alarm
When Gas Supply Pressure Difference > 0.1 MPa
Blender Alarm Noise
>57 dB(a)
Bleed
3lpm
Transport Package
Carton
Specification
63*62*11.5cm&55.5*38.5*48.5cm
Trademark
UN Medical
Origin
China
HS Code
9019200090
Production Capacity
10000/Year
Reference Price
$ 630.00 - 855.00

Product Description

UN-Medical  Air Oxygen Blender Double or Single

Model:UN3000

Medical Air Oxygen Blender Air Oxygen Mixer
Adult / Infant HFNC Machine:
 
· Medical device treatment: In addition to drug treatment, respiratory support treatments relying on medical devices, such as oxygen therapy, invasive mechanical ventilation, extracorporeal membrane oxygenation (ECMO), and circulatory support are of much helpful to those the most serious cases of pneumonia. It also plays an important role in the treatment of critically ill patients. It is time to introduce our high flow oxygen blender for replacement. It is very helpful for the early infection cases and the recovery patients from critical stages.
 
· High Flow Nasal Cannula(HFNC) oxygen therapy is a form of non -invasive respiratory support , which comprises an air oxygen blender , an active humidifier , a single heated circuit and a nasal cannula . It delivers adequately heated and humidified medical gas up to 10-60L/min , and is considered to have a number of physiological effects: reduction of anatomical dead space, PEEP effect, constant fraction of inspired oxygen and good humidification. It is widely used in RICU and ICU .

Medical Air Oxygen Blender Air Oxygen Mixer
Specification:
 
Adjustment Method of Oxygen Concentration Merchanical
FiO2 21%-100%
Flow 2-18LPM;1-10LPM and 10-120LPM
Pressure of gas source Air/Oxygen @ 0.3-0.4 Mpa
Blender Alarm When gas supply pressure difference > 0.1 Mpa
Blender Alarm Noise >57 dB(A)
Accuracy of FiO2 3%
Humidifier Supply Voltage/Frequency 220V/ 110V 50/60Hz
Humidifier Temperature monitoring 0-75ºC
Humidifier Heater Plate Over-temperature Cut Off 95±5ºC
Heater Wire(Max.) 22V-,2.73A, 60W, 50/60Hz
Humidifier Temperature control settings Heated wire mode(mode indicator lighted)
Temperature grade(with indicator status)  Continuous flow range  Delivered patient temperature
P1 (
· ○○)                                                            5L/min-60L/min            25-29ºC

P2 (
·· ○)                                                            5L/min-60L/min            29-35ºC

P3 (
··· )                                                            5L/min-60L/min            35-39ºC
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details)


Configuration and Package:

Medical Air Oxygen Blender Air Oxygen Mixer
Medical Air Oxygen Blender Air Oxygen Mixer
Medical Air Oxygen Blender Air Oxygen Mixer
Multiple Choices:
Medical Air Oxygen Blender Air Oxygen Mixer Medical Air Oxygen Blender Air Oxygen Mixer


Applications and Custom Choices:

HFNC Machine without Medical Air Compressor(Above)
HFNC Machine with Medical Air Compressor(Below)

Medical Air Oxygen Blender Air Oxygen Mixer





Exhibitions Image 
Medical Air Oxygen Blender Air Oxygen Mixer


Factory  Image 

Medical Air Oxygen Blender Air Oxygen Mixer
Medical Air Oxygen Blender Air Oxygen Mixer


Shipment and payment 

For the order which less than 20units, more of the customers choose the shipment by Express Courier or by Air Cargo.
Our normal Lead Time is within 5-7working days after payment.




Contact us:  Yuki. Cai