RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

Model NO.
JFRO-2T
Desalination Rate
99.5%
Recovery Rate
50%
Operating Pressure
0.8-1.2MPa
Designed Water Inlet
4t/H
Raw Water Pump
Cnp/Nyp/ (Optional)
Control Valve Brand
Fleck/Runxin
Producing Capacity
2t/H
Power
2.2kw
Membrane Elements
Dow/Hydranautics/Troy/Vontron(Optional)
Membrane Size
8040
Warranty
1year
Host Size
800X600X1600mm (Can Be Customized)
RO Frame
SUS304
Transport Package
Wooden Packing
Specification
3.5m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
500pieces/Year
Reference Price
$ 2,700.00 - 5,400.00

Product Description

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine
Reverse Osmosis Water Treatment Equipment 2tp Fully Auto Water Filter System

 

Unique characteristics of RO Water Treatment System

 

1. The single-membrane desalination rate can reach 99%, the desalination rate of the primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of the secondary reverse osmosis system can generally be stabilized above 98%.

2. Because the reverse osmosis equipment can effectively remove microorganisms, organic substances and inorganic substances such as iron and silicon, the quality of the effluent is higher than other methods.

3. The equipment has small footprint, compact structure, reliable operation and convenient operation.

4. The system is simple, the degree of automation is high, the fault is automatically shut down, and it has the function of automatic protection.

5. The recovery rate can reach more than 70%.

6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution.


RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

Definition of   RO Water Treatment System

 

The reverse osmosis water treatment system uses municipal water as raw water, passes through a pre-filter (water softener is optional), and reverse osmosis membrane treats the water.

Reverse osmosis water system is the raw water through the precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, It can remove more than 98% of soluble salts and more than 99% of colloid, microorganisms, particles and organic matter in water.

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

Technical Parameters of   RO Water Treatment System
 

Model JFRO-2000L
Host Size 2700x600x1600mm (can be customized)
Power 3KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 67%
Designed Water Inlet 3000L/h
Outlet Flow 2000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 8
Raw Water Pump CNP/NYP (Optional)
High Pressure Pump CNP/NYP (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP
Number of Membrane housing 4
Pipe Material

U-PVC/ Stainless steel (Optional)

 

Introduction of   RO Water Treatment System  Consumables

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

The pretreatment of reverse osmosis water treatment system can ensure the stable operation and service life of reverse osmosis device, and has the following functions:

 

(1) To prevent scaling on the film surface (including CaCo3, CaSO4, SrSO4, CaF2, SiO2, iron and aluminum oxide, etc.);

(2) to prevent colloidal substances and suspended solid particles fouling;

(3) to prevent pollution and blockage of organic matter;

(4) to prevent microbial fouling;

(5) to prevent oxidative damage to the film by oxidizing substances;

(6) Keep the water yield of reverse osmosis device stable.

 

Reverse osmosis water treatment pretreatment system: iron and manganese filter, multi-media filter, activated carbon filter, sodium ion exchanger, precision filter, ultrafiltration.
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine
Process flow of RO water treatment system:
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

Composition of   RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine
RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

RO System Water Machine Filter Drinking Water Treatment Plant Reverse Osmosis Water Treatment Machine

 



 

 

Reverse Osmosis System