What's YUKA Advatage?
1. Compressed air National standard founder;
2. Build a laboratory with Wuhan University;
3. With many patents and strong R&D ability;
4. Advanced thread processing technology and testing equipment
What's YUKA Product Advatage?
1.15 years serve life for filter housing under working condition from temperature 1.5~80ºC.Maxi. Pressure is 1.0Mpa.
2. 6000~8000 hours serve life for filter element,filtering performance up to 99%
3. Integrated die-casting filter up to 4 inch,flow rate up to 48m³/min;
4. Effectively filter solid particles up to
0.01 microns
, suspended oil up to
0.003 mg/m³
;
5. 7 filter element filter levels to meet different needs;
6. Surface anti-corrosion treatment increases wear resistance and the corrosion of the shell is low;
7. Equipped with an external drain to effectively remove condensate;
8. Sight Glass shows the drainage inside the filter;
9. The presence of a pressure indicator indicates when the filter element should be replaced;
10. The filter element can be replaced without the intervention of third-party personnel and special tools;
Ability to install filters on the wall;
11. Less pressure drop when the airflow passes.
7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
PF
|
AO
|
AA
|
AX
|
ACS
|
AR
|
AAR
|
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible
|
High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21
ºC)
,1ppm(w).
|
High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21
ºC
),0.01ppm(w)
|
Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21
ºC
),0.001ppm(w)
|
Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21
ºC
)
,
0.003ppm
(
w
)
|
Dust particles whose diameter more than 1μm can be removed
|
Dust particles whose diameter more than 0.01μm can be removed
|
International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade
|
PF
|
AO
|
AA
|
AX
|
ACS
|
AR
|
AAR
|
Size of solid particles(ISO12500-3)
|
5μm
|
1μm
|
0.01μm
|
0.01μm
|
-
|
1μm
|
0.01μm
|
Filtration performance of solid particles(ISO12500-3)
|
-
|
99.999+%
|
99.999+%
|
99.999+%
|
99.999+%
|
99.999+%
|
99.999+%
|
Filtration performance of oil(ISO12500-1)
|
50%
|
80+%
|
99.9+%
|
99.99+%
|
-
|
-
|
-
|
Residual oil content(ISO12500-1)
|
5mg/m³
|
0.6mg/m³
|
<0.01mg/m³
|
<0.001mg/m³
|
<0.004mg/m³
|
-
|
-
|
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
Model
|
Pipe size
|
Flow rates
|
Dimension (mm)
|
L/S
|
m
3
/min
|
scfm
|
W(Width)
|
D(Depth)
|
H(Height)
|
A
|
B
|
C(clearance for housing)
|
YF010
|
RC1/2"
|
16.7
|
1.0
|
35.3
|
96
|
79
|
261
|
29
|
198
|
118
|
YF020
|
RC3/4"
|
25.0
|
1.5
|
53.0
|
96
|
79
|
261
|
29
|
198
|
118
|
YF030
|
RC3/4"
|
30.0
|
1.8
|
63.6
|
96
|
79
|
295
|
29
|
233
|
153
|
YF040
|
RC1"
|
33.3
|
2.0
|
71.0
|
96
|
79
|
295
|
29
|
233
|
153
|
YF060
|
RC1"
|
60.0
|
3.6
|
127.0
|
138
|
111
|
403
|
37
|
296
|
208
|
YF070
|
RC1"
|
83.3
|
5.0
|
177.0
|
138
|
111
|
503
|
37
|
396
|
303
|
YF080
|
RC1-1/2"
|
125.0
|
7.5
|
265.0
|
138
|
111
|
503
|
37
|
396
|
303
|
YF090
|
RC2"
|
166.7
|
10.0
|
353.1
|
174
|
142
|
736
|
58
|
607
|
469
|
YF100
|
RC2-1/2"
|
216.7
|
13.0
|
459.0
|
174
|
142
|
736
|
58
|
607
|
469
|
YF110
|
RC2"
|
283.3
|
17.0
|
600.0
|
174
|
142
|
1016
|
58
|
887
|
794
|
YF120
|
RC2-1/2"
|
316.7
|
19.0
|
671.0
|
174
|
142
|
1016
|
58
|
887
|
794
|
YF130
|
RC3"
|
416.7
|
25.0
|
883.0
|
220
|
184
|
793
|
74
|
649
|
514
|
YF140
|
RC4"
|
466.7
|
28.0
|
989.0
|
220
|
184
|
793
|
74
|
649
|
514
|
YF150
|
RC3"
|
683.3
|
41.0
|
1448.0
|
220
|
184
|
1050
|
74
|
906
|
764
|
YF160
|
RC4"
|
800.0
|
48.0
|
1695.0
|
220
|
184
|
1050
|
74
|
906
|
764
|
Technical requirements
|
Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C.
|
Pressure
|
Barg
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
Psig
|
15
|
29
|
44
|
59
|
73
|
87
|
100
|
116
|
131
|
145
|
160
|
174
|
189
|
203
|
219
|
232
|
Correction factor
|
0.38
|
0.53
|
0.65
|
0.76
|
0.85
|
0.93
|
1.00
|
1.07
|
1.13
|
1.19
|
1.23
|
1.31
|
1.36
|
1.41
|
1.46
|
1.51
|
Product Application
YUKA Certificates
YUKA Patents
YUKA Factory
YUKA Facility
YUKA in Shanghai ComVac Asia & Hannover Messe Exhibition
YUKA Delivery
YUKA service:
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty
Q:Why choose us?
a. 22 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.
Frequently Asked Questions:
Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.
Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production.
Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.
Q4. Do you have a
warranty?
Yes, for filter, it is 1
year normally.
Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.