Datasheet
|
||||
Model Name
|
MAC 30KTL3-X LV
|
MAC 40KTL3-X LV
|
MAC 50KTL3-X LV
|
MAC 60KTL3-X LV
|
Input AC
|
||||
Recommended max. PV power
|
4.5KW
|
6kW
|
7.5kW
|
9kW
|
Max. input voltage
|
1100V
|
|||
Rated voltage
|
600V
|
|||
Start-up voltage
|
250V
|
|||
MPPT voltage range
|
200V-1000V
|
|||
Max. input current
|
37.5A/37.5A/25A
|
37.5A/37.5A/37.5A
|
50A/37.5A/37.5A
|
50A/50A/50A
|
Max. short circuit current
|
44A
|
44A
|
55A
|
55A
|
MPPT number/Max. input strings number
|
3/3/2
|
3/3/3
|
4/3/3
|
4/4/4
|
Output AC
|
|
|
|
|
Rated output power
|
30kW
|
40kW
|
50kW
|
60kW
|
Max. apparent output power
|
3.3kVA
|
4.4kVA
|
5.5kVA
|
6.6kVA
|
Max. output power
|
3.3kW
|
4.4kW
|
5.5kW
|
6.6kW
|
Rated grid voltage
|
230V/400V (340-440V)
|
|||
Rated grid frequency
|
50/60Hz
|
|||
Max. output current
|
48.3A
|
64.4A
|
80.5A
|
96.6A
|
Power Factor
|
0.8leading 0.8lagging
|
|||
THDi
|
<3%
|
|||
Efficiency
|
||||
Max. efficiency
|
98.7%
|
|||
EU efficiency
|
98.5%
|
|||
Protection
|
||||
DC reverse-polarity protection
|
Yes
|
|||
Short circuit protection
|
Yes
|
|||
Output over current protection
|
Yes
|
|||
Surge protection
|
Yes
|
|||
Grid monitoring
|
Yes
|
|||
Anti-islanding protection
|
Yes
|
|||
Temperature protection
|
Yes
|
|||
Integrated AFCI (DC arc-fault circuit protection)
|
Yes
|
|||
Integrated DC switch
|
Optional
|
|||
General Data
|
||||
Dimensions (W*H*D)
|
680/508/281mm
|
|||
Weight
|
52kg
|
|||
Topology
|
Transformerless
|
|||
Self consumption
|
<1W (night)
|
|||
Operating ambient temperature range
|
-25 ~ +60°C
|
|||
Relative humidity
|
0-100%
|
|||
Ingress protection
|
IP65
|
|||
Cooling concept
|
Natural convection
|
|||
Max. operation altitude
|
4000m
|
|||
Safety/EMC standard
|
IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4
|
|||
Features
|
||||
DC connection
|
H4/MC4(Optional)
|
|||
AC connection
|
Cable gland+OT terminal
|
|||
Display
|
OLED+LED/WIFI+APP
|