Intermediate Frequency Computerized Electrotherapy Apparatus

Model NO.
MCT-ZP-IC
Modulation Mode
Variable Frequency and Alternating Modulation
Temperature Range of Electrode Plates
38~55
Intermediate Frequency Output Current
0mA ≤output Current≤ 100mA
Intermediate Modulation Frequency Range
0~150Hz
Intermediate Modulation Frequency Wave
Sine, Square, Triangle, Exponential, Sharp, Sawtoo
Intermediate Frequency Range
2kHz~6kHz
Supply Voltage
220V±22V, 50Hz±1 Hz
Transport Package
Wooden Package for Export
Specification
CE
Trademark
MeCan
Origin
Guangzhou
Production Capacity
1000sets/Month
Reference Price
$ 180.00 - 450.00

Product Description

Intermediate Frequency Computerized Electrotherapy Apparatus
and Ultrasonic Physiotherapy Device

Model:  MCT-ZP-IC


Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus



Product performance:

1. Normal working conditions:
a) Environment temperature:+10 ºC ~+40 ºC
b) Relative humidity:30%~5%
c) Atmosphere pressure:700hPa~1060hPa
d) Rated power source:AC220V, rated frequency:50Hz
2.Rated input power:85VA
3.Host device overall dimension : L440mm , W360mm , H132m , Allowable error±20mm
4.Output channels: two-channel medium frequency with diathermy output, two-channel iontophoresis DC output, two-channel interference electrical output
5.Electrode line: 1800mm,permissible difference ±100mm
6. Square electrode plate : No.4. L:107mm , W:72mm , tolerance ±10 %
No.6.L:95mm,   W:60mm, tolerance ±10%
No.7.L:85mm,   W:55mm, tolerance ±10%
Circular plates: φ40mm in diameter, tolerance ±5mm
7.Working frequency : 1kHz ~ 10kHz , Single frequency tolerance±10%
8. Modulation frequency : 0 ~ 200Hz , Single frequency tolerance±10%
9. Medium frequency carrier waveform: two-way square wave, pulse width: 85us ~ 250us, tolerance ±10%
    Medium frequency modulation waveform: sine wave, square wave, triangular wave, exponential wave, sawtooth wave, sharp wave, etc
10.Modulation types: continuous, intermittent, intermittent, variable frequency, undense and alternate models
11. Medium frequency modulation amplitude: 50%, 75%, 100%, tolerance ±5%
12.Interference electrical performance: dynamic rhythm 4s ~ 10s; Different frequency change period is 15S~30S
13.Medium frequency treatment prescription:0~99 optional
14.Intermediate frequency(IF) output current: under the load of 500Ω,each channel of output current ≤100mA,0~99 adjustable
15. Output current stability: the change rate of output current under different loads should not be greater than 10%
16.Peak voltage of intermediate frequency: the peak voltage of the mid-frequency output shall not exceed 500V when measured in the open road condition.
17. Operation: when the output set to the maximum value, the output end will be run 10min first, then the short circuit runs for 5min. The therapeutic device should be able to work properly.
18. Temperature range of electrode plate:38 ºC ~55 ºC , 6 gears adjustable, tolerance ±3 ºC
19. Iontophoresis output current: under the load of 500Ω,each channel output current not more than 50mA, 0~99 adjustable.
20. Power plate: a qualified product with a class of medical device record certificate should be selected.
21.Treatment time: the IF treatment time is already in the prescription, there is sound cue when treatment time enough, then output stop. Tolerance ±1min
22.Load impedance: the effective load impedance is 500 Ω. The influence of technical indicators can be ignored when the rated load impedance varies in the period of ±10% 
23.Operation mode: running continuously.

Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus
Intermediate Frequency Computerized Electrotherapy Apparatus