RC1 /2" Precise Oil Vapor Adsorption Air Filter with Auto Drain

Model NO.
YF010
Resistance Corrosion
Inside and Outside
Parts
Dp Indicator, Auto Drain, Sight Glass
Flow Rate
1.0m³/Min
Color
Red
OEM & ODM Service
Yes
Diversion Fin Design on Element Top Cap
Less Pressure Loss
Element Top Cap Design
Colorful to Distinguish
Maxi. Operate Pressure
1.0MPa
Filtration Performance
From 5 μm to 0.01μm
Connection
RC1/2"
Operate Temperature
1.5~80ºC
Housing Serve Lige
15 Years
Element Serve Life
6000~8000 Hours
Material
Aluminum Alloy
Transport Package
Brown Inner Box & Cardboard
Specification
Dimension: 96 X 79X 261mm
Trademark
YUKA
Origin
China
HS Code
8421399090
Production Capacity
500PCS Per Days
Reference Price
$ 35.96 - 42.30

Product Description

Feature & Benefit
1. Aluminum Alloy material, 15 years serve life for filter housing under working condition from temperature 1.5ºC~80ºC .
    Maxi. Pressure is 1.0 Mpa.
2. 6000~8000 hours serve life for filter element,filtering performance up to 99%
3. Integrated die-casting filter up to 4 inch , flow rate up to 48m³/min .
4. Top cap of filter element with diversion fins, which will let the air come inside the filter more smooth, less pressure loss.


7 Grades Filter Element:  PF/AO/AA/AX/ACS/AR/AAR
PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21 ºC) ,1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21 ºC ),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21 ºC ),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21 ºC ) , 0.003ppm ( w ) Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed

                                                                             

 
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
Model Pipe size Flow rates Dimension (mm)
L/S m 3 /min scfm W(Width) D(Depth) H(Height) A B C(clearance for housing)
YF010 RC1/2" 16.7  1.0  35.3  96 79 261 29 198 118
YF020 RC3/4" 25.0  1.5  53.0  96 79 261 29 198 118
YF030 RC3/4" 30.0  1.8  63.6  96 79 295 29 233 153
YF040 RC1" 33.3  2.0  71.0  96 79 295 29 233 153
YF060 RC1" 60.0  3.6  127.0  138 111 403 37 296 208
YF070 RC1" 83.3  5.0  177.0  138 111 503 37 396 303
YF080 RC1-1/2" 125.0  7.5  265.0  138 111 503 37 396 303
YF090 RC2" 166.7  10.0  353.1  174 142 736 58 607 469
YF100 RC2-1/2" 216.7  13.0  459.0  174 142 736 58 607 469
YF110 RC2" 283.3  17.0  600.0  174 142 1016 58 887 794
YF120 RC2-1/2" 316.7  19.0  671.0  174 142 1016 58 887 794
YF130 RC3" 416.7  25.0  883.0  220 184 793 74 649 514
YF140 RC4" 466.7  28.0  989.0  220 184 793 74 649 514
YF150 RC3" 683.3  41.0  1448.0  220 184 1050 74 906 764
YF160 RC4" 800.0  48.0  1695.0  220 184 1050 74 906 764
Technical requirements Maximum operating pressure: 10 barg   Operating temperature: 1.5°C~80°C.
Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

                               RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain                          RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain                             RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain

YUKA Certificates
RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain


YUKA Patents
RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain



YUKA Factory

RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain

YUKA Facility
RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain


YUKA in Shanghai ComVac Asia & Hannover Messe Exhibition
RC1/2" Precise Oil Vapor Adsorption Air Filter with Auto Drain



YUKA Delivery




YUKA service:
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty


Q:Why choose us?
a. 22 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.

  
Frequently Asked Questions:

Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.
 
Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production. 
 
Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.
 
Q4. Do you have a   warranty?
Yes, for filter, it is 1   year normally.
 
Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.