Lab water purifier
The Smart N system is a compact solution that combines the production of pure water and ultrapure water in a single unit-eliminating the need for a pretreatment stage upstream of the ultrapure water system
Typical applications | |
BOD tests | IHC(Immunohistochemisry) |
COD tests | IVF(in vitro fertilization) |
DNA microarrays | LC-MS(Liquid chromatography-mass spectrometry) |
Electrochemistry | Kjeldahl analysis |
Electrophoresis | MALDI-TOF |
Enzyme immunoassays | Mammalian and bacterial cell culture |
GC/(Gas chromatography) | Northern and Southern blotting |
GFAAS/(Graphite Fumece Atomic Absorption Spectrophotometry) | PCR(Polymerase chain reaction) |
HPLC(High-Performance Liquid Chromatography) | Plant tissue culture |
IC(lon chromatography) | Qualitative analyses |
ICP-AES(Inductively Coupled Plasma Atomic Emission Spectrometry) | Ultra trace analysis |
ICPMS(Inductively Coupled Plasma Mass Spectrometry) | Western blotting |
Model | Smart N 15UV | Smart N 15VF | Smart N 30UV | Smart N 30VF |
Feed Water Requirement | ||||
Source | Tap water | Tap water | Tap water | Tap water |
Conductivity | <2000us/cm | <2000us/cm | <2000us/cm | <2000us/cm |
Hardness** | <450ppm as CaCO3 | <450ppm as CaCO3 | <450ppm as CaCO3 | <450ppm as CaCO3 |
Pressure | 0.05~0.5MPa(7-72psi) | 0.05~0.5MPa(7-72psi) | 0.05~0.5MPa(7-72psi) | 0.05~0.5MPa(7-72psi) |
Temperature | 5~40ºC | 5~40ºC | 5~40ºC | 5~40ºC |
Purification Water(Class III) | ||||
lonic Rejection | >95% | >95% | >95% | >95% |
Bacteria Rejection | >99% | >99% | >99% | >99% |
Conductivity | 1~20us/cm(RO-2 5us/cm) | 1~20us/cm(RO-2 5us/cm) | 1~20us/cm(RO-2 5us/cm) | 1~20us/cm(RO-2 5us/cm) |
Productivity Rate | 15L/h | 15L/h | 30L/h | 30L/h |
Ultrapurification Water(Class I) | ||||
Resistivity At 25ºC | 18.2MΩ.cm | 18.2MΩ.cm | 18.2MΩ.cm | 18.2MΩ.cm |
Conductivity At 25ºC | 0.055us/cm | 0.055us/cm | 0.055us/cm | 0.055us/cm |
TOC Level*** | 1~5ppb | 1~5ppb | 1~5ppb | 1~5ppb |
Endotoxin(Pyrogens)**** | N/A | <0.001EU/ml | N/A | <0.001EU/ml |
Particulate(≥0.02um) | <1pc/ml | <1pc/ml | <1pc/ml | <1pc/ml |
Bacteria*** | <0.1cfu/ml | <0.1cfu/ml | <0.1cfu/ml | <0.1cfu/ml |
Rnase/Dnase** | N/A | Free | N/A | Free |
Manual dispense flow rate | 1.5-2.0L/min | 1.5-2.0L/min | 1.5-2.0L/min | 1.5-2.0L/min |
Automatic dispense volume | 100~60000ml | 100~60000ml | 100~60000ml | 100~60000ml |
Electrical Requirements | ||||
Electrical Voltage | 110V/220V±10% | 110V/220V±10% | 110V/220V±10% | 110V/220V±10% |
Electrical Frequency | 50HZ/60HZ | 50HZ/60HZ | 50HZ/60HZ | 50HZ/60HZ |
Packing Information | ||||
Net Weight | ||||
Main units | 24kg | 24kg | 24kg | 24kg |
Water tank(30L) | 7kg | 7kg | 7kg | 7kg |
External Dimensions(W*D*H) | ||||
Main units | 315x525x570mm | 315x525x570mm | 315x525x570mm | 315x525x570mm |
Water tank(30L) | 380x380x595mm | 380x380x595mm | 380x380x595mm | 380x380x595mm |
Shipping weight | ||||
Main units | 37kg | 37kg | 37kg | 37kg |
Water tank(30L) | 15kg | 15kg | 15kg | 15kg |
Shipping Dimensions(W*DxH) | ||||
Main units | 525x610x770mm | 525x610x770mm | 525x610x770mm | 525x610x770mm |
Water tank(30L) | 520x440x615mm | 520x440x615mm | 520x440x615mm | 520x440x615mm |
Configuration | ||||
SMART-N System | Smart N 15UV | Smart N 15VF | Smart N 15UV | Smart N 30VF |
Pretreatment module | √ | √ | √ | √ |
High-pressure pump | √ | √ | √ | √ |
Reverse osmosis | √ | √ | √ | √ |
Dual wavelength UV-lamp | √ | √ | √ | √ |
Ultra-purification cartridge | × | × | × | × |
Microfiltration cartridge | √ | √ | √ | √ |
Point-of-use filter | √ | √ | √ | √ |
Storage tank 30L | √ | √ | √ | √ |
Air filter net for tank | √ | √ | √ | √ |
Remote water dispenser | √ | √ | √ | √ |
Typical applications | |
BOD tests | IHC(Immunohistochemisry) |
COD tests | IVF(in vitro fertilization) |
DNA microarrays | LC-MS(Liquid chromatography-mass spectrometry) |
Electrochemistry | Kjeldahl analysis |
Electrophoresis | MALDI-TOF |
Enzyme immunoassays | Mammalian and bacterial cell culture |
GC/(Gas chromatography) | Northem and Southam blotting |
GFAAS/(Graphite Fumece Atomic Absorption Spectrophotometry) | PCR(Polymerase chain reaction) |
HPLC(High-Performance Liquid Chromatography) | Plant tissue culture |
IC(lon chromatography) | Qualitative analyses |
ICP-AES(Inductively Coupled Plasma Atomic Emission Spectrometry) | Ultra trace analysis |
ICPMS(Inductively Coupled Plasma Mass Spectrometry) | Western blotting |
1. It has the function of constant quality and quantitative water intake, 0.1-25l quantitative water intake, and arbitrary water intake; Take water with fixed quality. If the water quality does not meet the standard, it will be recycled for treatment.
2. ultrafiltration has a backwashing function to effectively delay the service life(only Smart
For equipment usually, we offer ply-wooden cases with free fumigation or multilayer carton boxes. or customized foam or aluminum suitcase. For IVD reagents. we use a foam box with an ice bag to guarantee a suitable temperature.
Heal Force International Trading (Shanghai) Co., Ltd has always been committed to customer needs. By continuously improving product performance, perfecting product lines, and establishing a complete after-sales service center, we customize more reasonable, reliable, and valuable digital laboratory solutions for hospitals and university clients. Adhering to the vision of "Hea Force Leads You To Healthier Life", we continuously obtained an excellent reputation in biosafety protection, centrifugation, cell culture, water purification & gene amplification.