500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System

Model NO.
JFRO-500L
Desalination Rate
99.5%
Recovery Rate
50%
Operating Pressure
0.8-1.2MPa
Designed Water Inlet
1000L/H
Raw Water Pump
Cnp/Nyp/Grundfos (Optional)
Control Valve Brand
Fleck/Runxin
Warranty
1year
Host Size
800X600X1600mm (Can Be Customized)
RO Frame
SUS304
Membrane Elements
Dow/Hydranautics/Troy/Vontron(Optional)
Membrane Size
4040
Power
2.2kw
Producing Capacity
500L/H
Transport Package
Wooden Packing
Specification
3.5m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
1000pieces/Year
Reference Price
$ 900.00 - 2,700.00

Product Description

500LPH PLC Water Purification Plant Water Treatment Reverse Osmosis System


Pretreatment dosing problem

1. Dosing problems of flocculant and coagulant aid:

The turbidity of the source water, PH value, the content of iron ion and the type of drug added in the subsequent system determine the type and dosage of the flocculant and coagulant aid. And dosage must do adaptability and dosage optimization test. Many RO users in this aspect of the work is not in place, resulting in the clarification of the pool water quality is not good.

 

2. The dosing problem of fungicides

For organic matter and bacteria and microorganisms in raw water, the user usually uses oxidizing media to kill, such as sodium hypochlorite, liquid chlorine, chlorine dioxide, etc. For some surface water sources, the bactericidal effect is not ideal due to the long-term addition of the above medium. At present, non-oxidizing fungicides, such as ZDH-881 and MDC-881, have longer killing effect, and can save the cost of subsequent reducing agent addition.

 

3. The addition of reducing agent

The addition of reducing agent should take into account the thoroughness of the reduction effect and the bacterial contamination after excessive addition. It is often found that after the user adds too much, the bacterial slime on the filter element is generated.



500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System

What size unit of RO Water Treatment System do I need to purchase?

 

For different types of water, the limits of osmotic flux and elemental recovery in ro water treatment system are based on the correlation between SDI value and membrane contamination and the correlation between mineral content and elemental recovery respectively. For example, systems designed to have high permeability flux rates may experience higher scaling rates and more frequent chemical cleaning. The design of seawater systems is further limited by osmotic pressure and durability of membrane elements due to high salinity (> 36,000 PPM TDS).

 

Characteristics of   RO Water Treatment System

 

Compared with other water treatment methods, it has the advantages of no phase change, normal temperature operation, simple equipment, high efficiency, less occupation, convenient operation, less energy consumption, wide range of adaptation, high degree of automation and good effluent quality. Reverse osmosis desalination rate and purity of produced water are higher than electrodialysis, for high fluoride and low salinity brackish water desalination by reverse osmosis, effluent water quality can reach our daily drinking purified water health standards. And reverse osmosis desalination brackish water energy consumption - - electricity consumption, water consumption are lower than electrodialysis, and reverse osmosis equipment compact structure, small footprint, stable and reliable operation effect, in line with the "clean production" requirements, reverse osmosis is more reasonable than other methods, effective desalination brackish water method.

 

Ro water treatment system method is used to desalinate brackish water with different salt content. The desalting rate of the system is above 96 %, and the quality of desalted water reaches the standard of drinking water. The brackish water desalination device of reverse osmosis system has strong adaptability. It can realize continuous treatment of brackish water with different salt content by adjusting operation parameters according to the quality of raw water. The device is highly integrated and is expected to become a complete set of finalized equipment.

 

Technical Parameters of   RO Water Treatment System
 

Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)

 

Introduction of   RO Water Treatment System  Consumables

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

Classic model of reverse osmosis system:

 

1. Preferential adsorption capillary pore model: No pore was found under weak point dry state electron microscope. The wet membrane specimens are not electron microscopic samples.

2. Dissolution diffusion model: no holes are considered.

3. Dry closed wet open model: the most appropriate modern reverse osmosis mechanism model that can explain the unity of models 1 and 2. The "dry-closed wet-open" reverse osmosis model unifies the two most classical reverse osmosis mechanism models, the fine pore model and the dissolved diffusion model.


Process flow of RO water treatment system:
500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System

Composition of   RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System

500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System
500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System 500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System
500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System

500lph PLC Water Purification Plant Water Treatment Reverse Osmosis System